Service and maintenance
10.1 Error and diagnostics messages
SIMATIC MV500
234
Operating Instructions, 03/2021, C79000-G8976-C494-05
LED
labeling
Meaning
Description and corrective measures
ER
Red, permanently on:
The optical reader is in "Group error" mode
Possible causes when working with onboard
PROFINET IO:
•
Bus communication is interrupted.
•
Bus error (no physical connection to a
subnet / switch).
•
Wrong transmission speed,
Full duplex transmission is not enabled.
•
The IP address is incorrect.
•
Bad configuration.
•
Bad parameter assignment.
•
Bad or missing device name.
•
I/O controller not available / switched off.
Start the WBM to view the error message. Perform the sug-
gested corrective measures in the section "Error messages
(Page 224)".
•
Check whether the IP address or device name occurs
more than once in the network.
•
Check the settings of the I/O controller.
R/S
Permanently off:
The optical reader is in "Stop" mode.
No error
Green, permanently on:
The optical reader is in "RUN" mode.
No error
LK
Permanently off:
There is no Ethernet connection to the opti-
cal reader.
•
Check the connection to the Ethernet cable.
•
Check whether the connected switch or other communi-
cations partner is operational.
•
Check or replace the Ethernet cable.
Green, permanently on:
An Ethernet connection without data traffic
is available.
In order to start the WBM of the optical reader, you also
need a valid network configuration for TCP/IP. Here, for
example, you can use the SINEC PNI to create a valid net-
work configuration for TCP/IP.
Green flashing:
The optical reader is exchanging data.
No error
READ
Green flashing:
The read result is valid.
No error
The reading was successful and the read result is valid (OK).
Yellow, flashing:
The read result ended with a MATCH error.
The reading was successful, but the result comparison
showed a deviation from the default (MATCH error).
Red, flashing:
The read result is invalid (N_OK).
The reading was unsuccessful or the read result is not valid
(N_OK).
Possible causes:
•
The expected codes were not in the image.
•
The processing time was not sufficient.
•
A test condition could not be fulfilled.
Summary of Contents for SIMATIC MV500
Page 10: ...Preface SIMATIC MV500 10 Operating Instructions 03 2021 C79000 G8976 C494 05 ...
Page 16: ......
Page 28: ......
Page 32: ......
Page 92: ......
Page 114: ......
Page 148: ......
Page 244: ......
Page 254: ......
Page 260: ......
Page 292: ......
Page 294: ...Service Support SIMATIC MV500 294 Operating Instructions 03 2021 C79000 G8976 C494 05 ...