Process interfacing via an automation system (PLC, PC)
9.6 Control via TCP/IP and RS232
SIMATIC MV500
198
Operating Instructions, 03/2021, C79000-G8976-C494-05
•
Saving programs.
•
Setting "Digital out".
A control command is triggered in each case by the corresponding string.
Table 9- 53 Overview of all commands with a string
Command
String
Trigger
Identical to the configured string in the WBM
Write match string
You can find a description of the command in the section
"Write match string (Page 198)".
Set DISA bit
MDIH
Reset DISA bit
MDIL
Query status
MGST
Program change
(select program number)
MR<programnr>
Save program
with internal trigger
MI<programnr>
Save program
with external trigger
MT<programnr>
Reset command
MRES
Set digital out
MO<p1><p2><p3><p4><p5><p6>
9.6.1
Trigger
When the optical reader receives a character string that is identical to the configured
character string in the WBM, it triggers image acquisition and processing.
9.6.2
Write match string
Note
Sent match string takes effect immediately
A sent match string takes effect immediately. The sent match string is not synchronized with
the trigger signal or the processing of buffered acquired images.
Therefore, ensure that the match string is sent when no image acquisition is running.
Summary of Contents for SIMATIC MV500
Page 10: ...Preface SIMATIC MV500 10 Operating Instructions 03 2021 C79000 G8976 C494 05 ...
Page 16: ......
Page 28: ......
Page 32: ......
Page 92: ......
Page 114: ......
Page 148: ......
Page 244: ......
Page 254: ......
Page 260: ......
Page 292: ......
Page 294: ...Service Support SIMATIC MV500 294 Operating Instructions 03 2021 C79000 G8976 C494 05 ...