Connection
6.3 Connecting the reader
SIMATIC MV500
120
Operating Instructions, 03/2021, C79000-G8976-C494-05
Power IO RS232 cable
The Power-IO RS232 cable is used for the power supply, for connection to the DI/DQ
connections and, for example, for the communication connection of an S7 controller via the
RS232 interface.
Figure 6-2
Pin assignment of Power-IO-RS232 connector on the optical reader
①
NOTICE
Connect "IN_COMMON" or "OUT_COMMON"
In order to be able to use the inputs and outputs described below, you must connect the
"IN_COMMON" or "OUT_COMMON" signals.
Table 6- 1
Pin assignment Power-IO RS232 cable, M12 (female, 12-pin)
Pin
Color
Signal name
Meaning
1
A
White
INPUT - COMMON
Reference point 0 V or 24 V for inputs
2
B
Brown
RS422 TxD_P
Send line RS422 TxD positive
3
C
Green
RS422 TxD_N
Send line RS422 TxD negative
4
D
Yellow
OUTPUT 2
Digital output 2
5
E
Gray
OUTPUT - COMMON
Reference point 0 V or 24 V for outputs
6
F
Pink
RS232 TxD /
RS422 RxD_P
Send line RS232 / Receive line RS422 RxD
positive
7
G
Blue
DC 0V
0 V DC power supply
8
H
Red
DC 24V
24 V DC power supply
9
J
Black
STROBE (OUTPUT)
Signal output for connecting the external
ring light
10 K
Violet
TRIGGER / INPUT 1
Trigger input / digital input 1
11 L
Gray/pink
OUTPUT 3
Digital output 3
12 M
Red/blue
RS232 RxD /
RS422 RxD_N
Receive line RS232 / RS422 RxD negative
Summary of Contents for SIMATIC MV500
Page 10: ...Preface SIMATIC MV500 10 Operating Instructions 03 2021 C79000 G8976 C494 05 ...
Page 16: ......
Page 28: ......
Page 32: ......
Page 92: ......
Page 114: ......
Page 148: ......
Page 244: ......
Page 254: ......
Page 260: ......
Page 292: ......
Page 294: ...Service Support SIMATIC MV500 294 Operating Instructions 03 2021 C79000 G8976 C494 05 ...