Technical data
11.1 Technical specifications of SIMATIC MV500
SIMATIC MV500
246
Operating Instructions, 03/2021, C79000-G8976-C494-05
6GF3540-0xx10
6GF3550-0xx10
6GF3560-0xx10
Type of image capture
Global shutter with manual or automatic expo-
sure time
Operating distance
•
Mini lens:
70 ... 3000 mm
1)
•
EF lens:
Depending on the lens used
2)
Mounting type of lens
C-mount lens connection
Type of light source
Built-in ring lights or external ring lights
Image acquisition frequency (max.)
•
Device version S: 83 Hz
•
Device version H: 71 Hz
•
Device version U: 62 Hz
•
Device version X: 33 Hz
Type of focusing
•
Mini-lens: Manual adjustment on the lens
•
EF lens: Automatic setting via WBM
Supply voltage, current consumption, power loss
Supply voltage
24 V DC (19.2 to 28.8 V DC)
Current consumption (at 24 V DC)
•
Typical
•
0.2 A
•
0.4 A with ring light (continuous light)
•
Maximum
•
0.6 A
•
0.8 A with ring light (continuous light)
Mechanical specifications
Housing
•
Material
•
Die-cast aluminum (silicone-free)
•
Color
•
TI-Grey
Permitted ambient conditions
Ambient temperature
•
During operation
•
0 … +50 °C
•
During transportation and storage
•
-30 … +70 °C
Relative humidity (max.)
95%
Degree of protection
IP67 (according to IEC 60529)
3)
Shock resistance
IEC 60068-2
Shock acceleration
300 m/s²
Vibration acceleration
40 m/s²
Summary of Contents for SIMATIC MV500
Page 10: ...Preface SIMATIC MV500 10 Operating Instructions 03 2021 C79000 G8976 C494 05 ...
Page 16: ......
Page 28: ......
Page 32: ......
Page 92: ......
Page 114: ......
Page 148: ......
Page 244: ......
Page 254: ......
Page 260: ......
Page 292: ......
Page 294: ...Service Support SIMATIC MV500 294 Operating Instructions 03 2021 C79000 G8976 C494 05 ...