7-33
FM 453 Servo Drive / Step Drive Positioning Module
C79000-G7076-C453-01
When optimizing for several of the above criteria, you can determine the ma-
chine data from the results of the individual optimizations by a variety
of methods:
S
Guarantee of all partial results
–
Least determined value of MD38
–
Greatest value for each of MD40, MD41 and MD42
S
Prioritization of one optimization criterion
Set MD38 and MD40-MD42 to the values that match the highest-priority
optimization criterion for your application, and again evaluate response as
to the remaining criteria.
S
Taking the mean of partial results
Set MD38 and MD40-MD42 to the means of the individual partial results,
and again evaluate response as to all criteria.
Compromise
Optimization
Starting up the FM 453