4-2
FM 453 Servo Drive / Step Drive Positioning Module
C79000-G7076-C453-01
4.1
Wiring Diagram for a FM 453
Figure 4-1 shows how the individual components of the positioning controller
with FM 453 and a servo drive are linked together.
PG/PC
FM 453
SIMODRIVE
SIEMENS
Dig. inputs, e.g.
touch probe
MPI connecting cable
Setpoint cable
Measuring
system cables
Drive unit, e.g.
SIMODRIVE 611-A
e.g. absolute
encoder (SSI)
e.g. linear scale
with EXE
CPU
OP
SIMATIC S7-400
X5
X2 to X4
e.g. incremental en-
coder with RS 422
e.g. ROD 320
(built-in encoder in
1FT5 motor)
Dig. outputs, e.g.
direction of rotation
Front connector X1
5
6
7
8
9
10
11
12 13
14 15
16
17 18
PS
Channels 1 to 3
Fig. 4-1
Overview of Connecting Cables for a FM 453 with Servo Drive (example)
FM 453 with Servo
Drive
Wiring the FM 453