7-19
FM 453 Servo Drive / Step Drive Positioning Module
C79000-G7076-C453-01
Set
Servo = ON
Yes
END
Travel test using Start/Stop frequency
Start axis
Set
Frequency level 1 = f
ss
Frequency level 2 = f
max
Select
Mode = open-loop control
Frequency level 1
Plus or minus direction
(execute several times)
(make sure travel area is clear!)
Axis movement completed?
Step drive active?
(Motor torque present?)
Select
Frequency level 2
Check drive
Check MD:
MD 37.0 (RFG)
MD 37.17 bis MD 37.19
No
Yes
No
Direction correct?
No
Check MD:
MD54
MD37.19
Check MD:
MD19.1 (rot.dir.)
Yes
No
Yes
Restart test sequence
Start axis
Plus or minus direction
(execute several times)
(make sure travel area is clear!)
Axis movement completed?
(including correct braking?)
Travel at
f
max
Check MD:
MD55, MD57 to MD60
MD37.17 to MD37.19
Fig. 7-7
Basic Startup of Stepper Motor Actuation
Starting up the FM 453
Summary of Contents for SIMATIC FM 453