In the case of mixed configurations, the drives are permanently assigned to
the terminals of the separate channels.
You should always start with the step drives.
Example:
Connecting one step drive and two servo drives.
Step drive on channel 1
1. Servo drive on channel 2
2. Servo drive on channel 3.
Connecting two step drives and one servo drive.
1. Step drive on channel 1
2. Step drive on channel 2
Servo drive on channel 3
Connecting cable
The connecting cables are a cable set for three channels with:
S
One step drive and two servo drives
–
Order No.: 6FX2 002-3AB02-1
VVV
S
Two step drives and one servo drive
–
Order No.: 6FX2 002-3AB03-1
VVV
The connecting cable is available in a variety of lengths.
For length code, see
,
Order No.: E86060-K4490-A001-A4
FM 453
Connecting cable
X5
SIEMENS
SIEMENS
Drive unit e.g. FM STEPDRIVE
SIMODRIVE 611-A
READY2
(channels 1 to 3)
Fig. 4-8
Connecting to FM STEPDRIVE and SIMODRIVE Drive Units
In both configurations, the signal READY2 can be used alternately.