5-9
FM 453 Servo Drive / Step Drive Positioning Module
C79000-G7076-C453-01
Chapter 6 describes how to generate a user data block.
You can use “Parameterize FM 453” to fill the user DB with the data de-
scribed in Table 5-2.
The menu Target system
"
Online editing
"
User data allows you to select
and edit your user DB.
Table 5-2
User DB
Data Block
Significance
User DB
For the structure and data formats see Chapter 6
You can preload the following data to the DB provided the DB
itself has been loaded to the CPU:
S
Module address
1)
S
Channel address
1)
S
Channel offset
1)
S
Zero offset
S
Set actual value
S
Set actual value on-the-fly
S
Set reference point
S
Setpoint for increment
S
Speed level 1
S
Speed level 2
S
Voltage level 1
S
Voltage level 2
S
MDI block
S
MD block on-the-fly
S
Program selection, program number
S
Program selection, block number
S
Program selection, working direction
S
Code application data 1
S
Code application data 2
S
Code application data 3
S
Code application data 4
1) You can only view these data. The data are edited by the FC INIT_DB (see Chapter 6).