![Siemens SIMATIC FM 453 Manual Download Page 186](http://html.mh-extra.com/html/siemens/simatic-fm-453/simatic-fm-453_manual_378154186.webp)
8-2
FM 453 Servo Drive / Step Drive Positioning Module
C79000-G7076-C453-01
Using the keyboard of the operator panel, you can change the data/signals in
the data blocks:
S
Machine data
DB No. 1205 for channel 1
DB No. 1505 for channel 2
DB No. 1805 for channel 3
S
Increments
DB No. 1230 for channel 1
DB No. 1530 for channel 2
DB No. 1830 for channel 3
S
Tool offset data
DB No. 1220 for channel 1
DB No. 1520 for channel 2
DB No. 1820 for channel 3
S
Traversing programs
DB No. 1001...1199 for channel 1
DB No. 1301...1499 for channel 2
DB No. 1601...1799 for channel 3
The following data and signals can be displayed on the operator panel dis-
play:
S
Machine data, see above
S
Increments, see above
S
Tool offset data, see above
S
Traversing programs, see above
S
Status messages
DB No. 1000 for channel 1
DB No. 1300 for channel 2
DB No. 1600 for channel 3
e.g.
–
Operating data, such as actual values
–
Active NC blocks
–
Linear measurements
–
Actual value block change
–
Check-back signals and error conditions
–
Servicing data
The configuration package includes a pre-configured interface for the
COROS OP 17 device.
What Can I Control
on the FM 453?
What Can I
Monitor on the
FM 453?
Man-Machine Interface