2-3
FM 453 Servo Drive / Step Drive Positioning Module
C79000-G7076-C453-01
The motor is actuated by the power section and drives the axis.
The motor can be:
S
A servo motor, e.g. 1FT5
S
A stepper motor, e.g. SIMOSTEP
The encoder detects movement of the axis. It supplies pulses to the FM 453.
The number of pulses is proportional to the distance traversed. Stepper motor
operation is also possible without the encoder.
The CPU executes the user program.
These include not only the axis, but also gear trains and clutch systems.
All other additional equipment is covered by the term peripherals.
Peripherals mainly include:
S
Limit switches to limit the positioning range (safety devices).
S
The programming device/PC is used for:
–
Assigning parameters using the software “Parameterize FM 453”
–
Programming the FM 453 using function blocks
–
Test/startup
Motor
Encoder
CPU
Mechanical Trans-
mission Elements
Peripherals
Basic Principles of Positioning