![Siemens SIMATIC FM 453 Manual Download Page 162](http://html.mh-extra.com/html/siemens/simatic-fm-453/simatic-fm-453_manual_378154162.webp)
7-20
FM 453 Servo Drive / Step Drive Positioning Module
C79000-G7076-C453-01
7.3.4
Basic Startup of Servomotor Actuation
With the following startup actions, you verify that the servo motor will tra-
verse as a matter of course in response to actuation by the FM 453. You also
determine the time constants of the servo drive that are required in later opti-
mization steps for the servo position control.
Note
Always be sure to put MD modifications into effect with “Activate machine
data.”
!
Caution
Before triggering any traversing movement, be sure to check that there is
enough space for the axis to move in the desired direction.
You can use the following flow chart to check the actuation of the drive.
Overview
Drive Actuation
Starting up the FM 453