4-14
FM 453 Servo Drive / Step Drive Positioning Module
C79000-G7076-C453-01
Proceed as follows:
1. Open the cover of the FM 453 and plug the female sub-D connector onto
the module.
2. Lock the connector in place with the knurled screws. Close the connector
cover.
3. Open the front door of the FM STEPDRIVE and plug the male sub-D
connector onto the step drive.
4. Lock the connector in place with the knurled screws. Close the front door.
Connecting cable
The connecting cable is a cable set for three channels with a step drive.
Order No.:
6FX2 002-3AB04-1
VVV
The connecting cable is available in a variety of lengths.
For length code, see
,
Order No.: E86060-K4490-A001-A4
The following Figure shows you how to connect an FM 453 to FM STEP-
DRIVE drive units.
FM 453
Connecting cable
X5
SIEMENS
SIEMENS
Drive unit e.g. FM STEPDRIVE
READY2
(channels 1 to 3)
SIEMENS
Fig. 4-7
Connecting to FM STEPDRIVE Drive Units
In this configuration with step mode channels 1 to 3, the external signal
READY2 must be used for each channel.
Connecting Step
Drives
Wiring the FM 453