Installation
2-4
ET 200eco Distributed I/O Station
A5E00158716-02
Installation of the terminal block
1. Insert the terminal block into the I/O module.
2. Bolt the terminal block to the I/O module (with a torque of 1 to 1.3 nm). Tighten
the screws evenly in diagonally opposite sequence.
The terminal block is equipped with four captive screws (see Figure 2-2).
2
1
2
2
2
Figure 2-2
Inserting and screw–tightening the terminal block at the I/O module
Note
The protection type IP 65, IP 66 or IP 67 is only ensured after the terminal block is
screwed tight onto the I/O module!
2.4
Label replacement
Properties
You can use these labels to identify each of the I/O module’s channels and the
terminal block. The system is supplied with snap–on labels:
•
8 labels on the I/O module
•
1 label on the terminal block
Requirements
Replacement labels are available on order. For order numbers please refer to
Appendix A.
Summary of Contents for SIMATIC ET 200eco
Page 8: ...Preface viii ET 200eco Distributed I O Station A5E00158716 02 ...
Page 18: ...Product overview 1 6 ET 200eco Distributed I O Station A5E00158716 02 ...
Page 70: ...Commissioning and diagnostics 4 16 ET 200eco Distributed I O Station A5E00158716 02 ...
Page 116: ...I O address area C 6 ET 200eco Distributed I O Station A5E00158716 02 ...
Page 124: ...Index Index 4 ET 200eco Distributed I O Station A5E00158716 02 ...