Configuration / project engineering
5.7 Configuration with the Command Line Interface
SCALANCE W786-xPRO
184
Operating Instructions, Release 08/2007, C79000-G8976-C221-02
CLI
\
SYSTEM
\
SYSLOG>
Comment
Command Description
IWLAN/
PB LINK
W744 W746 W747 W78x
W78x
RR
info
Shows the current Syslog
configuration.
✔
✔
✔
✔
✔
✔
Can only be changed with Admin rights.
server [IP address]
Specifies the IP address of the
Syslog server.
✔
✔
✔
✔
✔
✔
Can only be changed with Admin rights.
logs [ D | E ]
Specifies whether the log
entries are also sent to the
Syslog server.
✔
✔
✔
✔
✔
✔
Can only be changed with Admin rights.
auths [ D | E ]
Specifies whether the
authentication log entries are
also sent to the Syslog server.
✔
✔
✔
✔
✔
✔
See also
SSyslog menu command (Page 104)
5.7.2.12
CLI
\
SYSTEM
\
SNTP menu command
Time-of-day synchronization in the network
With the commands in this menu, you specify the SNTP server and the time zone.
CLI
\
SYSTEM
\
SNTP>
Comment
Command Description
IWLAN/
PB LINK
W744 W746 W747 W78x
W78x
RR
server [IP address]
Specifies the IP address of the
SNTP server.
ᅳ
✔
✔
✔
✔
✔
tzone [hours]
Specifies the deviation of the
time zone of the SCALANCE W-
700 according to UTC (Universal
Time Conversion) in hours.
ᅳ
✔
✔
✔
✔
✔
See also
SNTP Config menu command (Page 106)