Configuration / project engineering
5.7 Configuration with the Command Line Interface
SCALANCE W786-xPRO
180
Operating Instructions, Release 08/2007, C79000-G8976-C221-02
5.7.2.6
CLI
\
SYSTEM
\
EMAIL menu command
Sender and recipient of an E-mail
With the commands in this menu, you specify that the device sends an E-mail when certain
events occur. You can also set a sender address.
CLI
\
SYSTEM
\
Comment
Command Description
IWLAN/
PB LINK
W744 W746 W747 W78x
W78x
RR
mail [E|D]
Enable / disable the E-mail
service.
ᅳ
✔
✔
✔
✔
✔
Several E-mail addresses can be entered separated by
semicolons.
email [E-mail address]
Specifies the address(es) to
which the SCALANCE W-700
sends E-mails.
ᅳ
✔
✔
✔
✔
✔
smtp <IP address>
[:port number]
Specifies the IP address and
the port number of the SMTP
server.
ᅳ
✔
✔
✔
✔
✔
from [text for sender
field]
Specifies the sender of E-
mails from SCALANCE W-
700.
ᅳ
✔
✔
✔
✔
✔
See also
E-mail Config menu command (Page 103)
5.7.2.7
CLI
\
SYSTEM
\
SNMP menu command
Enabling SNMP
With the commands in this menu, you configure general SNMP parameters (enabling SNMP,
traps and community strings)
CLI
\
SYSTEM
\
SNMP>
Comment
Command Description
IWLAN/
PB LINK
W744 W746 W747 W78x
W78x
RR
Enables / disables SNMPv1, v2c, v3 and traps.
snmp [E|D]
Enables / disables SNMP.
ᅳ
✔
✔
✔
✔
✔
Enables / disables SNMPv1, v2c and traps.
snmpv1 [E|D]
Enables / disables
SNMPv1/v2c.
ᅳ
✔
✔
✔
✔
✔