SCALANCE W786-xPRO
Operating Instructions, Release 08/2007, C79000-G8976-C221-02
225
Upkeep and maintenance
6
6.1
Loading new firmware over FTP
Procedure
You can load new firmware on a SCALANCE W-700 over FTP even if the device is not
reachable over WEB Based Management or the CLI. This may be the situation if there was a
power down during a firmware update. Follow the steps below to load new firmware using
FTP:
1.
Turn off the power to the device.
2.
Now press the Reset button and reconnect the power to the device while holding down
the button.
3.
Hold down the button until the red fault LED (F) starts to flash after approximately 2
seconds.
4.
Now release the button. The bootloader waits in this state for a new firmware file that you
can download by FTP.
5.
Connect a PC to the SCALANCE W-700 over the Ethernet interface.
6.
Assign an IP address to the SCALANCE W-700 with the Primary Setup Tool.
7.
Open a DOS box and change to the directory where the file with the new firmware is
located and then execute the command "ftp <ip address>".
As an alternative, you can use a different FTP client.
8.
Enter "siemens" as both the login and password.
9.
Load the new firmware with the command "put <firmware>".
10.
Once the firmware has been transferred completely to the device, the device is restarted
automatically.