Configuration / project engineering
5.6 Configuration with Web Based Management
SCALANCE W786-xPRO
100
Operating Instructions, Release 08/2007, C79000-G8976-C221-02
5.6.3.2
IP Settings menu command
Configuration
Here, you decide whether you will use a DHCP server or whether you want to assign a fixed
IP address to the SCALANCE W-700. You can also set the IP address of a router and the
default TTL. The TTL (time to live) parameter specifies the maximum number of routers
passed through by a data packet before it is discarded.
Note
If you use a Radius server for authentication, this must the accessible over the management
VLAN.
See also
CLI
\
SYSTEM
\
IP menu command (Page 176)
5.6.3.3
Services menu command
Configuration
Here, you select the services with which access to the device will be possible. If, for
example, the "SNMP Enabled" check box is not selected, neither write nor read access is
possible using the SNMP protocol (v1,v2c,v3). If the SNMP protocol is not permitted, it is not
possible to send SNMP traps.
To improve security, you should only enable the services that you actually use.
NOTICE
Over SNMP, it is possible to disable all services and to allow read access only over SNMP.
Following this, no further configuration of the device is possible.
If you only want to enable secure access over HTTPS when configuring the device,
select the "HTTPS only" check box.
If you want to enable the response of the device to Ping signals, select the "Ping enabled"
check box.
With the integrated SSH server, you have secure access to the CLI. In contrast to Telnet, the
entire communication including user authentication is encrypted.
Notes on WEB Enabled in the WEB interface
The check box for the "WEB Enabled" entry is selected and inactive because configuration
with Web Based Management is no longer possible without the option of access with HTTP.