Configuration / project engineering
5.6 Configuration with Web Based Management
SCALANCE W786-xPRO
168
Operating Instructions, Release 08/2007, C79000-G8976-C221-02
With the "Print graph" button, it is easy to print the table. You will, however, need to make
certain settings in the browser.
●
Mozilla Firefox 1.5:
In the "File" => "Page setup..." dialog, make sure that the "Print Background (colors &
images) check box is enabled in the "Options" group box.
●
Microsoft Internet Explorer 6.0:
In "Tools" => "Internet Options" => "Advanced", the "Print background colors and images"
check box must be enabled under "Printing".
The signal recorder itself does not cause any significant load in the network that could affect
other processes.
Both parts of the signal recorder can be operated independently.
Below, you will find a few tips that will help you to obtain useful measurements with the
signal recorder:
●
Use a fixed data rate in the configuration.
●
Where possible, the ipcf mode with as low an update time as possible should be set for
the measurements.
●
Make sure that there is enough data communication during the measurement because
the statistics functions evaluate incoming frames.
●
The measurement setup should be run through 2-3 times with the same parameters to
find out whether losses of signal strength always occur at the same position.
●
Selective measurements at a fixed position should be made over a certain time.