Configuration / project engineering
5.6 Configuration with Web Based Management
SCALANCE W786-xPRO
110
Operating Instructions, Release 08/2007, C79000-G8976-C221-02
C-PLUG State
input box
This displays the status of the C-PLUG. The following are possible:
●
ACCEPTED
There is a C-PLUG with a valid and matching content inserted in the device.
●
NOT ACCEPTED
No C-PLUG or C-PLUG inserted but invalid or incompatible content. The status is also
displayed when the C-PLUG was formatted during operation.
●
NOT ACCEPTED, HEADER CRC ERROR
A C-PLUG with bad content is inserted.
●
NOT PRESENT
There is no C-PLUG inserted in the device.
C-PLUG Device Group
input box
Indicates the SIMATIC NET product line that used the C-PLUG previously.
C-PLUG Device Type input box
Indicates the device type within the product line that used the C-PLUG previously.
Configuration Revision
input box
The version of the configuration structure. This information relates to the configuration
options supported by the device and has nothing to do with the concrete hardware
configuration. This revision information does not therefore change if you add or remove
modules or extenders, it can, however, change if you update the firmware.
File System
input box
Displays the type of file system on the C-PLUG.
File System Size
input box
Displays the maximum storage capacity of the file system on the C-PLUG.
File System Usage
input box
DDisplays the memory utilization of the file system of the C-PLUG.
C-PLUG Info String
input box
Here, you will see all the additional information about the device that used the C-PLUG
previously, for example, order number, type designation, and the versions of the hardware
and software.
Modify C-PLUG drop-down list box, Modify button
You can only make settings in this box if you are logged on as "Admin". Here, you decide
how you want to change the content of the C-PLUG. The following alternatives are possible: