Configuration / project engineering
5.7 Configuration with the Command Line Interface
SCALANCE W786-xPRO
178
Operating Instructions, Release 08/2007, C79000-G8976-C221-02
CLI
\
SYSTEM
\
EVENT>
Commands available only for access points and client modules (not for IWLAN/PB LINK):
Comment
Command Description
IWLAN/
PB LINK
W744 W746 W747 W78x W78x
RR
setec CW <E|D> <E|D>
<E|D> <E|D>
Reactions when the
SCALANCE W-700 restarts.
ᅳ
✔
✔
✔
✔
✔
If the error status was triggered only due to a link down
event, the error states is cleared and the error LED goes
off.
setec LU <E|D> <E|D>
<E|D>
Reaction to the "Link Up"
event on the Ethernet
interface.
ᅳ
✔
✔
✔
✔
✔
setec LD <E|D> <E|D>
<E|D>
Reaction to the "Link Down"
event on the Ethernet
interface.
ᅳ
✔
✔
✔
✔
✔
The SNMP trap "AuthFault" is sent only if there is a bad
SNMP authentication.
setec AF <E|D> <E|D>
<E|D>
Reaction to a bad
authentication over Web
Based Management, CLI, or
SNMP.
ᅳ
✔
✔
✔
✔
✔
setec PM <E|D> <E|D>
<E|D> <E|D>
Reaction to a change of
power supply over the M12
power connection.
ᅳ
✔
✔
✔
✔
✔
setec PE <E|D> <E|D>
<E|D> <E|D>
Reaction to a change of
power supply over Ethernet.
ᅳ
✔
✔
✔
✔
✔
setec FC <E|D> <E|D>
<E|D>
Reaction to a change in the
error status.
ᅳ
✔
✔
✔
✔
✔
Commands available only for access points (not for access points in client mode, clients, IWLAN/PB
LINK):
Comment
Command Description
IWLAN/
PB LINK
W744 W746 W747 W78x W78x
RR
setec AP <E|D> <E|D>
<E|D> <E|D>
Reaction to detection of an
access point on own or an
overlapping wireless channel.
ᅳ
ᅳ
ᅳ
ᅳ
✔
✔
This command is available only with the following
models:
•
SCALANCE W788-1RR
•
SCALANCE W788-2RR
•
SCALANCE W784-1RR
setec MS <E|D> <E|D>
<E|D> <E|D>
Reaction when the update time
in iPCF mode with PNIO support
cannot be kept to due to an
additional client.
ᅳ
ᅳ
ᅳ
ᅳ
ᅳ
✔