Assembly
3.3 Mounting without an adapter (wall mounting only)
SCALANCE W786-xPRO
36
Operating Instructions, Release 08/2007, C79000-G8976-C221-02
Option: Threaded holes on rear of housing
When a wall is extremely thin, it is often not possible to use wall plugs for the screws. To
allow wall mounting even in this situation, there are four M4 threaded holes on the rear of the
SCALANCE W786. The drilling template is a square with sides 100 mm long. The device can
therefore be mounted on a wall with bolts through the wall.
Calculate the length of the required M4 screws as follows:
Screw length = wall thi 7 mm