Configuration / project engineering
5.6 Configuration with Web Based Management
SCALANCE W786-xPRO
Operating Instructions, Release 08/2007, C79000-G8976-C221-02
149
●
Local Port
Here, you enter the number of the local port of the Ethernet device.
Note
The following instructions apply only to the IP parameter assignment using the PST tool.
When the module is accessed with PST by a configuration computer, the address
assignment differs depending on the interface:
•
PST over the wireless interface:
The "global" address is changed.
•
PST over the Ethernet interface:
The "local" address is changed.
See also
CLI
\
BRIDGE
\
NAT menu command (Page 209)
CLI
\
BRIDGE
\
NAT
\
STATIC menu command (Page 209)
5.6.6.9
IP Mapping Table menu command
Note
This menu command is available only with the following variants:
•
SCALANCE W746-1PRO
•
SCALANCE W746-1
•
SCALANCE W747-1RR
•
SCALANCE W747-1
•
SCALANCE W78x in client mode
Note
IP mapping table
If layer 2 tunneling is configured for a client, the IP mapping table is not displayed.
WLAN access by several devices over a client
With the devices listed in the first paragraph, you can provide access to the WLAN for
several devices with one client. This means that you do not need to equip every device with
its own wireless client.
This so-called IP mapping is possible only if the connected devices are addressed only by IP
frames. Communication at MAC address level (ISO/OSI layer 2) can
●
be established with one component whose MAC address is configured on the client,