Configuration / project engineering
5.6 Configuration with Web Based Management
SCALANCE W786-xPRO
102
Operating Instructions, Release 08/2007, C79000-G8976-C221-02
Note
By resetting all the defaults, the IP address is also lost. The device can then only be
accessed using the Primary Setup Tool unless the IP address is obtained over DHCP.
If you are logged on as user, the "Restore Factory Defaults" button is not visible.
See also
CLI
\
SYSTEM
\
RESTARTS menu command (Page 178)
5.6.3.5
Event Config menu command
System events of the device
On this page, you specify how the device reacts to system events. You can configure the
reaction of the SCALANCE W-700 to the following events:
●
Starting the device
●
Change in the Ethernet status Link up / Link down
●
Error when a user logs in
●
Change in the power supply of the device (evaluating this event only makes sense when
there is a redundant power supply).
●
Change in the error status (error LED)
Additional system events for access points
If you use a SCALANCE W78x in access point mode, you can configure additional system
events:
●
Events associated with a client logging on and off
●
IP-Alive state change (application-specific connection monitoring)
●
Link Check state change (device-specific connection monitoring)
●
Events related to bandwidth reservation iQoS
●
Detection of access points on own or an overlapping wireless channel
●
Topology changes in Rapid Spanning Tree
●
Events related to iPCF with the device variants SCALANCE W78x-xRR
●
Events in conjunction with the Forced Roaming on IP down function
●
Change in the WDS connection status Link up / Link down
With the device models that have more than one WLAN interface, the status of a redundant
connection (redundant, not redundant, interrupted) is also a system event.