Quick Setup Guide

This 

Quick Setup Guide

 provides step-by-step instructions on how to 

field-install the Ruckus Wireless T610s access point (AP).
For detailed information on planning the installation, performing a site 
survey, and operating the T610s, refer to the 

ZoneFlex Outdoor 

Access Point User Guide

, available at 

https://

support.ruckuswireless.com

.

WARNING:

 

Only trained and qualified personnel should be allowed to 

install, replace, or service this equipment.

 

WARNING: 

Installation of this equipment must comply with local and 

national electrical codes.

 

CAUTION:

 

Make sure that you form a 80mm - 130mm (3”-5”) drip 

loop in any cable that is attached to the AP or the building. This will 
prevent water from running along the cable and entering the AP or the 
building where the cable terminates. 

CAUTION:

 

Be sure that grounding is available and that it meets local 

and national electrical codes. For additional lightning protection, use 
lightning rods and lightning arrestors.

 

CAUTION:

 

Make sure that proper lightning surge protection 

precautions are taken according to local electrical code.

 

WARNING:

 

Ruckus Wireless strongly recommends that you wear eye 

protection before mounting the T610s.

T

HIS

 G

UIDE

 

IN

 O

THER

 L

ANGUAGES

请从以下网站获得该指南的简体中文版

 

https://support.ruckuswireless.com

.

Vous trouverez la version française de ce guide à l'adresse suivante 

https://support.ruckuswireless.com

.

こ の ガ イ ド の⽇本語版は 

https://support.ruckuswireless.com

 

で ご覧 く だ さ い。

 

가이드의

 

한국어

 

버전은

 

 

사이트

(

https://support.ruckuswireless.com

)

에서

 

확인하시기

 

바랍니다

.

Veja a versão em português (Brasil) deste guia em 

https://support.ruckuswireless.com.

Puede ver la versión en español (América Latina) de esta guía en 

https://support.ruckuswireless.com.

B

EFORE

 Y

OU

 B

EGIN

Before deploying your Ruckus Wireless T610s, verify that all items 
listed in 

Package Contents

 are included in the package. If any item is 

damaged or missing, notify your authorized Ruckus Wireless sales 
representative. Also, make sure that you have the required hardware 
and tools. 

R

EQUIRED

 H

ARDWARE

 

AND

 T

OOLS

Customer-supplied outdoor-rated three-wire (1-2mm

2

 or 14-

18AWG) AC cable

1/2” (13mm) flat-blade screwdriver or equivalent

No. 2 Phillips screwdriver

Small flat-blade screwdriver

Torque wrench or torque screwdriver with sockets

Long-nose pliers

Electrical wire stripping and terminal crimping pliers

Pipe or pole --OR-- a sturdy flat surface

Electric drill with drill bits and customer-supplied wall anchors, flat 
washers, and hex nuts for flat-surface mount

Four factory-supplied 1/2” (12.7mm) wide stainless steel 
adjustable clamps, 2.5” (63.5mm) diameter, for main mounting 
bracket on smaller poles

Ruler

P

ACKAGE

 C

ONTENTS

A complete T610s field installation package includes all of the items 
listed below (see Figure 1for illustrations):

T610s Access Point (A)

Two M25 data cable glands (B)

Ground wire with lug (C)

Service Level Agreement/Limited Warranty Statement

Declaration of Conformity

Regulatory Statement

Ruckus Wireless AP Getting Started Guide

This Quick Setup Guide

Figure 1:

Package Contents

NOTE:

 

The outdoor AP Mounting Bracket and security cable are 

optional accessories that must be purchased separately. 

CAUTION!

The minimum software revision for the T610s 

is ZoneDirector (ZD) 9.13.1 or later, or SmartZone (SZ) 3.4 
or later, or standalone AP firmware 104.0 or later.

DO NOT CONNECT THE T610s TO A RUCKUS 
WIRELESS ZONEDIRECTOR RUNNING 9.13 OR 
EARLIER.

Summary of Contents for T610s

Page 1: ...m português Brasil deste guia em https support ruckuswireless com Puede ver la versión en español América Latina de esta guía en https support ruckuswireless com BEFORE YOU BEGIN Before deploying your Ruckus Wireless T610s verify that all items listed in Package Contents are included in the package If any item is damaged or missing notify your authorized Ruckus Wireless sales representative Also m...

Page 2: ...le gland base 7 Hand tighten the sealing nut STEP 2 ATTACHING THE U JOINT BRACKET TO THE MOUNTING BRACKET NOTE The following mounting instructions require purchase of optional accessories that are not included in the standard T610s package The outdoor AP Mounting Bracket and safety cable are optional accessories that must be purchased separately 1 Position the U joint bracket on the mounting brack...

Page 3: ...set The linkage bracket is symmetrical and either end can be attached to the AP bracket NOTE Make sure that linkage bracket is installed with its serrated external tooth lock washer on the inside of the AP bracket flanges This ensures that the elevation adjustment does not change 1 As described in Step 4 Mounting the Linkage Bracket to the U Joint Bracket loosely assemble the AP bracket shown in F...

Page 4: ...like remove the two 3mm hex screws remove the cap and insert the dongle into the USB port Once installed replace the cap and the hex screws and torque the screws to 7 in lbs Figure 14 Installing a USB dongle TROUBLESHOOTING CAUTION If required you can reset the AP to its factory default settings by pressing the reset button located inside the PoE IN port DO NOT DO THIS UNLESS SO INSTRUCTED Doing t...

Reviews: