background image

Teldat Connect-4GE Router

Teldat Dm591-I

Copyright© Version 2.3 Teldat S.A.

Teldat S.A.

Manual

Teldat Connect-4GE Router

1

Summary of Contents for Connect-4GE

Page 1: ...Teldat Connect 4GE Router Teldat Dm591 I Copyright Version 2 3 Teldat S A Teldat S A Manual Teldat Connect 4GE Router 1 ...

Page 2: ... A offers no warranty whatsoever for information contained in this manual Teldat S A is not liable for any direct indirect collateral consequential or any other damage connected to the deliv ery supply or use of this manual Manual Teldat S A 2 Teldat Connect 4GE Router ...

Page 3: ...g 3 Chapter 3 Components and Power Supply 4 3 1 Components 4 3 1 1 Front Panel 4 3 1 2 Rear Panel 4 3 1 3 Side Panels 5 3 1 4 Underside Panel 5 3 1 5 Top Panel LEDs 6 3 2 Assembly 7 3 2 1 Mounting in rack 7 3 2 2 Standalone 7 3 2 3 Wall mounting 7 3 2 4 Installing a DIN rail mount accessory Optional 9 3 3 Power Source 9 3 3 1 External Power Source 9 3 3 2 PoE 10 3 3 3 Connecting to the power sourc...

Page 4: ...ng 17 B 2 Updating the software 17 B 3 Connectors 18 B 3 1 LAN Connector 18 B 3 2 WWAN Connector female 18 B 3 3 Power Supply Connector 18 B 4 Technical Specifications 18 B 4 1 Hardware Architecture 18 B 4 2 LAN Interface 19 B 4 3 Wireless WAN Interface 19 B 4 4 Power Supply 19 B 4 5 External Power Supply 19 B 4 6 Dimensions and weight 19 B 4 7 Environmental Specifications 19 Table of Contents Tel...

Page 5: ...r supply requirements Elements you can connect to the device while it is running Installation and removal procedures for modules and power supplies A description of the device LEDs and connectors Troubleshooting 1 5 What is not in this manual This manual does not contain information relative to the device software nor does it contain information on the con figuration For information on configuring...

Page 6: ...Fax 34 918 076 566 Email support teldat com 1 8 Related documentation Dm748 I Software Updating 1 About This Guide Teldat S A 2 Teldat Connect 4GE Router ...

Page 7: ...ware Monitoring The Teldat Connect 4GE router hardware is monitored through the LEDs panel The LEDs provide visual information on what is happening in the device They indicate the state of the hardware components whether there is connectiv ity or not data flows etc For further information on the LED panel please see the section on Components on page 4 in the following chapter Teldat S A 2 Teldat C...

Page 8: ... Components 3 1 1 Front Panel Figure 1 shows the front panel Here you can find one of the WWAN antenna connectors and the slot for SIM card in sertion Fig 1 Front Panel The front panel elements are as follows FRONT PANEL ELEMENTS Table Item Description A WWAN antenna connector B Slot for the SIM card 3 1 2 Rear Panel Figure 2 shows the rear panel Here you can find other Teldat Connect 4GE connecto...

Page 9: ...section on the RESET Button on page 11 further on in this chapter B ETHERNET Gigabit Ethernet C Power source connection PSU 3 1 3 Side Panels Two WWAN antennas are located on the side panels one on either side Fig 3 Right hand side panel Fig 4 Left hand side panel 3 1 4 Underside Panel The following elements can be found on the underside panel Teldat S A 3 Components and Power Supply Teldat Connec...

Page 10: ...rforations to install a DIN rail mount Optional 3 1 5 Top Panel LEDs The LED panel provides information on the state of the components whether they are active or not and on network activity Fig 6 LED Panel The Teldat Connect 4GE LEDs are shown in Figure 6 The following table contains a description LEDs table LED Status Description 3 Components and Power Supply Teldat S A 6 Teldat Connect 4GE Route...

Page 11: ...The Teldat Connect 4GE cannot be mounted in a rack However there are other types of mounting 3 2 2 Standalone The Teldat Connect 4GE can be placed as a standalone on a flat stable surface Make sure there is enough space around the router for ventilation purposes and that electricity cables can reach it 3 2 3 Wall mounting The Teldat Connect 4GE can be mounted on the wall There are two slots on the...

Page 12: ...ontally apart on a wall or any other vertical surface The screws should protrude 0 6 cm 0 25 inch from the surface of the wall Caution If you install the screws in drywall use hollow wall anchors 8mm 5 16 inch to secure the screws If the screws are not properly anchored the strain of the cables connected to the router back panel could pull the router from the wall Step 2 Hang the router on the scr...

Page 13: ... exposure to sunlight and to other heat sources should be avoided The device should not be placed amongst papers magazines or other elements that could hinder natural air circulation The device should not be placed very close to strong electromagnetic fields such as speakers engines etc Knocks and or strong vibrations should be avoided during transport operation and storage Warning The electric cu...

Page 14: ...onnect the PoE adapter to the router The Teldat Connect 4GE can be powered through an Ethernet cable provided it complies with the POE 802 3aF standard The ETHERNET port is enabled for this To connect the Ethernet cable with PoE power to the router please carry out the steps included in the If the Ethernet cable is PoE on page 11 Figure 11 illustrates how to connect the PoE injector to the device ...

Page 15: ...the power supply from the electricity supply Disconnect the data cables 3 4 RESET Button The different features of the RST button are described below 3 4 1 Rebooting the device To reboot the device once it is operating normally press the RST button this restarts the router 3 4 2 Default Configuration The RST button allows you to boot the device with its default configuration through the following ...

Page 16: ...s installed Some cellular telephony technologies use the antenna diversity technique to improve the quality of the signal re ceived HSUPA CDMA EV DO LTE etc As a result the Teldat Connect 4GE router family incorporates various WWAN connectors Fig 13 The WWAN Antennas seen from the front panel When the antennas are not directly connected to the router but are installed through extension cords the m...

Page 17: ...ot recommend installing antennas near or between racks containing communication devices computers etc Use an extension cable and place the device outside The following recommendations are applicable to all wireless devices Do not touch or move the antenna while the device is transmitting or receiving Do not handle any equipment that contains devices which radiate and keep it far from any exposed p...

Page 18: ... Then press it until it is totally inserted To extract it press it again and remove it 3 Components and Power Supply Teldat S A 14 Teldat Connect 4GE Router ...

Page 19: ...Appendix A Safety information A 1 Translated Safety Warnings 0 1 Connect 2 Disconnect 3 4 35 6789 18 7 89 2 91 9 3 5 53 853 773 2 3 3 3 Teldat S A Safety information Teldat Connect 4GE Router 15 ...

Page 20: ...struction manuals for end users shall include the following information Model WA 12M12R Manufacturer Name ASIAN POWER DEVICES INC APD Manufacturer Address NO 5 LANE 83 LUNG SOU ST TAO YUAN CITY TAIWAN R O C Input Voltage 100 240 Vac Input AC frequency 50 60 Hz Output voltage 12 0 V Output current 1 0 A Output power 12 0 W Average active efficiency 88 6 Efficiency at low load 10 73 8 No load power ...

Page 21: ...the soft ware A failure in the downloading process may have damaged the current software im age stored in the memory of the device This may occur for instance when the device is turned off before buffering is complete The device will then start up with special software and configuration modes You may access the device through IP address 192 168 1 1 24 and use FTP to re start the uploading process ...

Page 22: ... POE B POE A POE B POE B B 3 2 WWAN Connector female WWAN Connector PINOUT ANT Internal External RF in out GND B 3 3 Power Supply Connector Power Supply Connector PINOUT ANT Internal External POSITIVE NEGATIVE B 4 Technical Specifications B 4 1 Hardware Architecture PROCESSORS Freescale P1014 MEMORY DDR3 1Gbit 128 MByte STORAGE UNIT FLASH Memory 128 Mbits 16 Mbytes Appendix B Teldat S A 18 Teldat ...

Page 23: ...n Please check the module manual CONNECTOR 3RF SMA female per module ANTENNA Depends on the type of Wireless WAN module Please check the antenna catalog for Cellular interfaces B 4 4 Power Supply INPUT VOLTAGE 12V DC INPUT CURRENT 1200 mA JACK 5 5 mm INTERNAL PIN 2 5 mm B 4 5 External Power Supply INPUT VOLTAGE 100 240V AC INPUT CURRENT 1 0 A INPUT FREQUENCY 50 60 Hz B 4 6 Dimensions and weight TY...

Page 24: ...B 4 7 Environmental Specifications TEMPERATURE OPERATING NORMALLY 0ºC to 45ºC STORED 25ºC to 70ºC RELATIVE HUMIDITY On 5 to 90 Appendix B Teldat S A 20 Teldat Connect 4GE Router ...

Reviews: