Error Messages and Trouble-Shooting
9-2
FC 56
J31069-D0155-U001-A0-7618
9.1
General Errors
Programmable controller assumes STOP.
S
A slave has failed, and OB 86 is not programmed.
S
A slave has failed, and OB 122 is not programmed.
This error does not occur until the FC 56 is called.
S
The pointers Params_DB, command_DB or DAT_DB do not exist or are
pointing to a nonexistent address area.
9.2
Error Classes
An error state always exists on the FC 56 when the “error” variable is set for a
channel. When this happens, the exact cause of the error can be determined with
the “error_code” variables.
The “error_code” variable is a double word consisting of 4 ASCII characters. The
first character is an alphanumeric character identifying the error class.
Table 9-1
Error classes of the FC 56
Error Class
Meaning
Axxx
Protocol error
Bxxx
SLG error
Cxxx
MDS error
Dxxx
Job-related errors
Exxx
Directory-related errors
Fxxx
File-related errors
Hxxx
Error messages of the FC 56
Type H8xx messages belong to a special class of FC 56 errors. These
errors are reported by the communication blocks of the controller.
Kxxx
Errors in the parameterization of QUEUE-READ and QUEUE-WRITE
Summary of Contents for MOBY FC 56
Page 12: ...Introduction 1 6 FC 56 J31069 D0155 U001 A0 7618 ...
Page 63: ...5 1 FC 56 J31069 D0155 U001 A0 7618 Sample Applications 5 ...
Page 80: ...Sample Applications 5 18 FC 56 J31069 D0155 U001 A0 7618 ...
Page 90: ...Entry Exit Check of an MDS in an SLG Field 6 10 FC 56 J31069 D0155 U001 A0 7618 ...
Page 94: ...System Configuration 7 4 FC 56 J31069 D0155 U001 A0 7618 ...
Page 100: ...Commissioning Guidelines 8 6 FC 56 J31069 D0155 U001 A0 7618 ...
Page 101: ...9 1 FC 56 J31069 D0155 U001 A0 7618 Error Messages and Trouble Shooting 9 ...
Page 152: ...Programming MOBY ASM on PROFIBUS DP V1 B 30 FC 56 J31069 D0155 U001 A0 7618 ...