Short Description of the ASM Hardware
A-4
FC 56
J31069-D0155-U001-A0-7618
Interfaces and indicators of the ASM 475
Description, Causes, Remedy
Hardware is defective (RAM, flash, ...)
Loader is defective (can only be fixed
at the plant).
Firmware is being loaded or no firm-
ware detected.
→
Load firmware.
→
Do not turn off ASM.
Firmware loading terminated with error
→
New start required.
→
Load firmware again.
→
Check update files.
Operating system error
→
Turn ASM on/off
ASM has booted and is waiting for a
RESET (init_run) from the user.
ERR_2
ON (perm.)
OFF
OFF
2 Hz
5 Hz
1 x flash
every 2 sec
Status and error indicators
SLG 1
S+
S–
E+
E–
SLG 2
S+
S–
E+
E–
SLG connection diagram
The numbers for the
connection refer to plug
connector X1 on the top
of the housing.
ASM475
SF
DC5 V
ACT_1
ERR_1
PRE_1
RxD_1
ACT_2
ERR_2
PRE_2
RxD_2
MOBY
SF:
System fault (hardware error on
ASM)
DC 5 V:
24 V are connected to ASM and the
5 V on ASM are okay.
ACT_1, ACT_2:
SLG is busy processing a user
command.
ERR_1, ERR_2:
A flashing pattern indicates the error
which occurred last.
PRE_1, PRE_2:
Indicates the presence of an MDS
RxD_1, RxD_2:
Indicates communication with SLG.
May also indicate malfunctions on
SLG.
The following ASM states are indicated with the LEDs PRE, ERR and SF.
ERR_1
ON (perm.)
ON
OFF
2 Hz
5 Hz
1 x flash
every 2 sec
PRE_2
OFF/ON
OFF
2 Hz
2 Hz
5 Hz
OFF
PRE_1
OFF/ON
OFF
2 Hz
2 Hz
5 Hz
OFF
SF
ON
ON
OFF
OFF
Any
OFF
6GT2 002-0GA10
Figure A-2
Interfaces and indicators of the ASM 475
Summary of Contents for MOBY FC 56
Page 12: ...Introduction 1 6 FC 56 J31069 D0155 U001 A0 7618 ...
Page 63: ...5 1 FC 56 J31069 D0155 U001 A0 7618 Sample Applications 5 ...
Page 80: ...Sample Applications 5 18 FC 56 J31069 D0155 U001 A0 7618 ...
Page 90: ...Entry Exit Check of an MDS in an SLG Field 6 10 FC 56 J31069 D0155 U001 A0 7618 ...
Page 94: ...System Configuration 7 4 FC 56 J31069 D0155 U001 A0 7618 ...
Page 100: ...Commissioning Guidelines 8 6 FC 56 J31069 D0155 U001 A0 7618 ...
Page 101: ...9 1 FC 56 J31069 D0155 U001 A0 7618 Error Messages and Trouble Shooting 9 ...
Page 152: ...Programming MOBY ASM on PROFIBUS DP V1 B 30 FC 56 J31069 D0155 U001 A0 7618 ...