MOBY Commands
4-29
FC 56
J31069-D0155-U001-A0-7618
4.2.16
ASM/SLG-STATUS
Parameterizing the command in Command_DB
Table 4-25
UDT 50 “MOBY FH CMD” – ASM/SLG-STATUS
Address
Name
Starting
Value
Commentary
0.0
+0.0
UID
DW#16#0
Not used
+4.0
command
’S’
MDS command: S = fetch STATUS of the ASM/SLG
+5.0
sub_command_1
B#16#0
Set mode of the ASM/SLG-STATUS command
00H
01H
02H
03H
04H
Read version and last command
Read hardware states of the SLG (only MOBY U)
SLG diagnosis I (only MOBY U)
SLG diagnosis II (only MOBY U)
SLG diagnosis III (only MOBY U)
+6.0
sub_command_2
B#16#0
Not used
+7.0
sub_command_3
B#16#0
Not used
+8.0
Filename
’xxxxxxxx’
Not used
+16.0
length
L#1
Not used
+20.0
address_MDS
W#16#0
Not used
+22.0
DAT_DB_number
48
Data DB. The status data are written to this
DB.
+24.0
DAT_DB_address
0
Address of the beginning of the user data in
the data DB
+26.0
QUEUE_DB_number
48
Not used
+28.0
QUEUE_DB_address
0
Not used
=30.0
Acknowledgment data in the ASM/SLG-STATUS command
Starting at address DAT_DB_address, data block DAT_DB_number contains the
requested data. The data are defined in an UDT so that the user can evaluate this
information.
For the definition of the data structure, see chapter 5.6 (UDT 110/120/130/
140/170).
Summary of Contents for MOBY FC 56
Page 12: ...Introduction 1 6 FC 56 J31069 D0155 U001 A0 7618 ...
Page 63: ...5 1 FC 56 J31069 D0155 U001 A0 7618 Sample Applications 5 ...
Page 80: ...Sample Applications 5 18 FC 56 J31069 D0155 U001 A0 7618 ...
Page 90: ...Entry Exit Check of an MDS in an SLG Field 6 10 FC 56 J31069 D0155 U001 A0 7618 ...
Page 94: ...System Configuration 7 4 FC 56 J31069 D0155 U001 A0 7618 ...
Page 100: ...Commissioning Guidelines 8 6 FC 56 J31069 D0155 U001 A0 7618 ...
Page 101: ...9 1 FC 56 J31069 D0155 U001 A0 7618 Error Messages and Trouble Shooting 9 ...
Page 152: ...Programming MOBY ASM on PROFIBUS DP V1 B 30 FC 56 J31069 D0155 U001 A0 7618 ...