Programming MOBY-ASM on PROFIBUS-DP-V1
B-27
FC 56
J31069-D0155-U001-A0-7618
The following data records have been implemented on the MOBY-ASM for
communication.
Table B-3 Data record numbers
Data
Record No.
Present on MOBY-ASM
Description
0
1
All
All
Reserved
Reserved
101
102
All
ASM 475
Parameterization channel 1
Parameterization channel 2
111
112
All
ASM 475
Data transmission channel 1
Data transmission channel 2
150
151
239
246
248
255
ASM 475, 473
ASM 475, 473
ASM 475, 473
ASM 475, 473
ASM 475, 473
All
Reserved (diagnosis of power
parameters)
Reserved (diagnostic buffer)
FW update (optional)
Reserved (read FW version)
Reserved (SZL list)
Reserved
Data record 10x
Each of data records (DR) 101 and 102 parameterizes one MOBY channel.
DR 10x must contain a RESET command. After the module starts up, DR 10x
must be sent to each MOBY channel. The channel is not ready for operation until
this is done.
A DR 10x is also accepted during normal operation. DR 10x interrupts a running
command. The user receives no further acknowledgment for the interrupted
command.
Data record 11x
DRs 111 and 112 are used for sending the actual commands and related
acknowledgments (all commands except RESET).
Summary of Contents for MOBY FC 56
Page 12: ...Introduction 1 6 FC 56 J31069 D0155 U001 A0 7618 ...
Page 63: ...5 1 FC 56 J31069 D0155 U001 A0 7618 Sample Applications 5 ...
Page 80: ...Sample Applications 5 18 FC 56 J31069 D0155 U001 A0 7618 ...
Page 90: ...Entry Exit Check of an MDS in an SLG Field 6 10 FC 56 J31069 D0155 U001 A0 7618 ...
Page 94: ...System Configuration 7 4 FC 56 J31069 D0155 U001 A0 7618 ...
Page 100: ...Commissioning Guidelines 8 6 FC 56 J31069 D0155 U001 A0 7618 ...
Page 101: ...9 1 FC 56 J31069 D0155 U001 A0 7618 Error Messages and Trouble Shooting 9 ...
Page 152: ...Programming MOBY ASM on PROFIBUS DP V1 B 30 FC 56 J31069 D0155 U001 A0 7618 ...