MOBY Commands
4-25
FC 56
J31069-D0155-U001-A0-7618
Presentation of the MDS data in UDT 100 with sub_command_1 = 01
Table 4-20
UDT 100 “MDS-STATUS”
Address
Name
Type
Commentary
0.0
STRUCT
+0.0
UID
DINT
MDS number
+4.0
MDS_type
BYTE
84 Hex = MDS with 2 kbytes
86 Hex = MDS with 32 kbytes
+6.0
sum_subframe_
access
DINT
Sum of the subframe accesses
+10.0
sum_searchmode_
access
INT
Sum of the searchmode accesses
+12.0
ST_date_Week
BYTE
Date of the last sleep_time change
(calendar week 1 to 53)
+13.0
ST_date_Year
BYTE
Date of the last sleep_time change
(calendar year, example: 01 = 2001)
+14.0
battery_left
INT
Remaining battery lifetime in percentage
+16.0
ST
BYTE
Sleep time Value set on the MDS
Statistically, the tolerance range is equally
distributed for each MDS.
Value
00
01
02
03
04
05
06
07
Sleep Time
20 msec
40 msec
80 msec
160 msec
320 msec
640 msec
1280 msec
2560 msec
Tolerance
"
6.7 msec
"
13.3 msec
"
26.7 msec
"
53.3 msec
"
106.7 msec
"
213.3 msec
"
426.7 msec
"
853.3 msec
=18.0
END_STRUCT
Summary of Contents for MOBY FC 56
Page 12: ...Introduction 1 6 FC 56 J31069 D0155 U001 A0 7618 ...
Page 63: ...5 1 FC 56 J31069 D0155 U001 A0 7618 Sample Applications 5 ...
Page 80: ...Sample Applications 5 18 FC 56 J31069 D0155 U001 A0 7618 ...
Page 90: ...Entry Exit Check of an MDS in an SLG Field 6 10 FC 56 J31069 D0155 U001 A0 7618 ...
Page 94: ...System Configuration 7 4 FC 56 J31069 D0155 U001 A0 7618 ...
Page 100: ...Commissioning Guidelines 8 6 FC 56 J31069 D0155 U001 A0 7618 ...
Page 101: ...9 1 FC 56 J31069 D0155 U001 A0 7618 Error Messages and Trouble Shooting 9 ...
Page 152: ...Programming MOBY ASM on PROFIBUS DP V1 B 30 FC 56 J31069 D0155 U001 A0 7618 ...