Programming MOBY-ASM on PROFIBUS-DP-V1
B-9
FC 56
J31069-D0155-U001-A0-7618
0
1
2/3
4/5
6/7
8/9
10
Command codex
’I’
:
FORMAT
(Format)
’B’
:
CREATE
(Open file)
’Q’
:
QUEUE-WRITE
(Set up complete data medium)
’E’
:
QUEUE-READ
(Read several files)
’U’
:
UPDATE
(Write complete file)
’W’ :
WRITE
(Write)
’R’
:
READ
(Read)
’D’
:
DELETE
(Delete)
’Y’
:
ATTRIB
(Set access rights for a file)
’C’
:
COVER
(Protect MDS structure)
’G’
:
DIR
(Read file directory)
’F’
:
MDS-STATUS
(Request MDS status)
’K’
:
END
(Conclude communication with MDS)
’T’
:
TRACE
(absolute read)
’M’ :
MOVE
(Read MDS directory out from ASM)
’L’
:
LOAD
(Transmit directory to ASM)
’A’
:
SET-ANT
(Turn antenna on/off)
‘P’
:
GET
(Read UIDs of all MDSs)
’S’
:
ASM-STATUS
(ASM status request)
’X’
:
RESET
(Reset Filehandler)
’N’
:
NEXT
(Process Next MDS)
7 6 5 4 3 2 1 0
Telegram heading (always present)
res.
ABS
res.
EMPF
res.
LFN
CC
CI
Command
ADB
DBN
DBL
User data
The user data depends on the command
(Cf. appendices B.5 and B.6.)
Length of user data following (dual)
Current data block number (dual)
Total number of data blocks to be transmitted (dual)
Command index
’I’
:
MOBY I command from ASM
xx
:
MOBY I status byte: acknowledgement from ASM
reserved
(always 00)
1 = Command terminated with error; the user
data contains error information. See
1 = Only with ECC: data from the MDS has been
corrected and is OK.
1 = The RAM battery is poor or exhausted (always
set for EEPROM MDS).
1 = Aux. battery is poor or exhausted (only valid for
MDS 507; otherwise always 1).
1 = WARNING: MDS was outside the transmission window
during command processing.
1 = WARNING: File read had length = 0.
1 = An MDS with a new directory has entered: the bit is set when the filehandler
has carried out a read operation on the complete MDS directory. In some
applications, the new directory can be backed up by the MOVE command.
The result of the last command will be delayed by the directory operation.
reserved for sequence number
(The filehandler transmits the parameter LFN from the command in the acknowledgement. It is not
evaluated by the filehandler)
reserved for receiver recognition* (presently always 00)
reserved for sender identifier* (MOBY I: code ’F’ is reserved for STG )
... 239
* The filehandler interchanges sender and receiver identifiers.
Figure B-6
General telegram layout
Summary of Contents for MOBY FC 56
Page 12: ...Introduction 1 6 FC 56 J31069 D0155 U001 A0 7618 ...
Page 63: ...5 1 FC 56 J31069 D0155 U001 A0 7618 Sample Applications 5 ...
Page 80: ...Sample Applications 5 18 FC 56 J31069 D0155 U001 A0 7618 ...
Page 90: ...Entry Exit Check of an MDS in an SLG Field 6 10 FC 56 J31069 D0155 U001 A0 7618 ...
Page 94: ...System Configuration 7 4 FC 56 J31069 D0155 U001 A0 7618 ...
Page 100: ...Commissioning Guidelines 8 6 FC 56 J31069 D0155 U001 A0 7618 ...
Page 101: ...9 1 FC 56 J31069 D0155 U001 A0 7618 Error Messages and Trouble Shooting 9 ...
Page 152: ...Programming MOBY ASM on PROFIBUS DP V1 B 30 FC 56 J31069 D0155 U001 A0 7618 ...