The Parameter Data Block
3-4
FC 56
J31069-D0155-U001-A0-7618
Table 3-2
INPUT-Parameter
Variable
Description
Priority_RW
Priority_RWD
These two variables are used to define which commands will be permitted for this
Priority_RW
0
1
1
Meaning
Only type “R” commands are allowed. The
MDS does not need to be written.
Type “R” and “W” commands are allowed.
User data can be read and written.
All commands are allowed. The MDS can
be formatted.
Priority_RWD
0
0
1
Priority*
“R”
(Read)
“W”
(Write)
“D”
(Delete)
MOBY_mode
Setting of the MOBY operating mode
1 Reserved for setting the mode with switches or GSD parameterization. Various
interfaces without switches automatically select MOBY I mode when
MOBY_mode = 0.
2 The UID parameter in the command can be disregarded.
3 The UID parameter in the command must be provided with the correct MDS num-
Remember:
MOBY_mode may only be changed after an ASM is turned on.
0
1
4
5
6
–
1
475; 473; 452
452
475; 473; 452
475; 473; 452
Value Operating Mode
ASM Type
Default
MOBY I (without MDS 507)
2
MOBY I with MDS 507
2
MOBY U – without multitag handling
2
MOBY U – with multitag handling
3
Summary of Contents for MOBY FC 56
Page 12: ...Introduction 1 6 FC 56 J31069 D0155 U001 A0 7618 ...
Page 63: ...5 1 FC 56 J31069 D0155 U001 A0 7618 Sample Applications 5 ...
Page 80: ...Sample Applications 5 18 FC 56 J31069 D0155 U001 A0 7618 ...
Page 90: ...Entry Exit Check of an MDS in an SLG Field 6 10 FC 56 J31069 D0155 U001 A0 7618 ...
Page 94: ...System Configuration 7 4 FC 56 J31069 D0155 U001 A0 7618 ...
Page 100: ...Commissioning Guidelines 8 6 FC 56 J31069 D0155 U001 A0 7618 ...
Page 101: ...9 1 FC 56 J31069 D0155 U001 A0 7618 Error Messages and Trouble Shooting 9 ...
Page 152: ...Programming MOBY ASM on PROFIBUS DP V1 B 30 FC 56 J31069 D0155 U001 A0 7618 ...