The Parameter Data Block
3-2
FC 56
J31069-D0155-U001-A0-7618
Table 3-1
UDT 10 “MOBY Param”
Address
Name
Type
Starting
Value
Commentary
0.0
STRUCT
+0.0
ASM_address
INT
0
Input:address of ASM (cycle word)
+2.0
ASM_channel
INT
1
Input: number of channel (1 to 4)
+4.0
command_DB_number
INT
47
Input:number of command DB
+6.0
command_DB_address
INT
0
Input:first address of commands in the
command DB
+8.0
MDS_IO_control
BYTE
B#16#1
Input:setup the MDS controlling
(0, 1, 4, 5)
+9.0
ECC_mode
BOOL
FALSE
Input: working with ECC check
+9.1
reserved01
BOOL
FALSE
+9.2
Priority_RW
BOOL
FALSE
Input: TRUE = Read and write commands
are allowed.
+9.3
Priority_RWD
BOOL
FALSE
Input: TRUE = Read, write and delete
commands are allowed.
+10.0
MOBY_mode
BYTE
B#16#1
Input: MOBY working mode (1, 4, 5, 6)
+11.0
scanning_time
BYTE
B#16#0
Input: scan time for long-range
MOBY I/U
+12.0
SLG_number
WORD
W#16#FFFF
Input: number of the SLG station
+14.0
distance_limiting
BYTE
B#16#F
Input: range limit
+15.0
multitag
BYTE
B#16#1
Input: max. no. of MDS permitted in
field
+16.0
field_ON_control
BYTE
B#16#0
Input: working mode of BERO
+17.0
field_ON_time
BYTE
B#16#0
Input: time has be of BERO
+18.0
ANZ_MDS_present
BOOL
FALSE
MDS is present
+18.1
ANZ_DIR_change
BOOL
FALSE
MDS with new directory
+18.2
ANZ_ECC
BOOL
FALSE
Error correction done
+18.3
ANZ_Read_0
BOOL
FALSE
Warning: Read file has length of 0.
+18.4
LR_bat
BOOL
FALSE
battery of the MDS 507
+18.5
battery_low
BOOL
FALSE
battery check has indicated low
voltage
+18.6
error
BOOL
FALSE
error during command processing has
appeared
+18.7
ready
BOOL
FALSE
command chain has been finished
+19.0
reserved02
BOOL
FALSE
+19.1
command_start
BOOL
FALSE
set: startup signal for command or
command chain
+19.2
reserved03
BOOL
FALSE
+19.3
init_run
BOOL
TRUE
set: Reset ASM and parameterize again
+19.4
ASM_failure
BOOL
FALSE
OB122 set: ASM removed from PROFIBUS
+19.5
FC56_active
BOOL
FALSE
FC is active
+19.6
ANZ_next
BOOL
FALSE
last command was NEXT
+19.7
ANZ_reset
BOOL
FALSE
last command was RESET
+20.0
ASM_busy
BOOL
FALSE
a command is processed by ASM
+20.1
reserved04
BOOL
FALSE
+20.2
ANZ_presence_change
BOOL
FALSE
An MDS entered the field or left the
field.
+20.3
ANZ_MDS_lost
BOOL
FALSE
Warning: MDS left the field while be-
ing processed.
+21.0
number_MDS
BYTE
B#16#0
number of MDS actual in field
+22.0
error_code
DWORD
Error indication of interface module
or FC
+26.0
version_MOBY
ARRAY
W#16#0
firmware version of MOBY
+30.0
to
+299.0
Internal FC variables. May not be
changed by the user.
=300.0
END_
STRUCT
Summary of Contents for MOBY FC 56
Page 12: ...Introduction 1 6 FC 56 J31069 D0155 U001 A0 7618 ...
Page 63: ...5 1 FC 56 J31069 D0155 U001 A0 7618 Sample Applications 5 ...
Page 80: ...Sample Applications 5 18 FC 56 J31069 D0155 U001 A0 7618 ...
Page 90: ...Entry Exit Check of an MDS in an SLG Field 6 10 FC 56 J31069 D0155 U001 A0 7618 ...
Page 94: ...System Configuration 7 4 FC 56 J31069 D0155 U001 A0 7618 ...
Page 100: ...Commissioning Guidelines 8 6 FC 56 J31069 D0155 U001 A0 7618 ...
Page 101: ...9 1 FC 56 J31069 D0155 U001 A0 7618 Error Messages and Trouble Shooting 9 ...
Page 152: ...Programming MOBY ASM on PROFIBUS DP V1 B 30 FC 56 J31069 D0155 U001 A0 7618 ...