Block Specifications
2-3
FC 56
J31069-D0155-U001-A0-7618
2.2
Configuration Overview
Table 2-2
Overview of MOBY FC 56 configuration
LAD Box
Parameter
Data Type
Permissible
Range
Description
MOBY FC
Params DB
Params_DB
Params ADDR
INT
INT
2 to 32767
0 300 600 *
Parameter data block number for
a MOBY channel (SLG)
Address pointer in the parameter
Params_DB
Params_ADDR
Params_ADDR
INT
0, 300, 600,*....
Address pointer in the parameter
data block to the start of a UDT 10
* These values are examples when only type UDT-10 data structures are used. These values change when
UDT 10 is followed by the MOBY command (UDT 50).
Params_DB and Params_ADDR make up a pointer to a data structure. This data
structure is defined by calling UDT 10 (English) or UDT 11 (German). A separate
data structure must be defined for each MOBY channel (ASM or SLG). See
chapter 2.3.