The Parameter Data Block
3-7
FC 56
J31069-D0155-U001-A0-7618
3.2
Command and Status Word “BEST”
The
control bits
of FC 56 are defined in the command and status word.
The command and status word with the variables is generated with UDT 10. The
following figure shows the variables and their relative addresses in UDT 10.
reserved02
command_start
reserved03
ASM_failure
FC56_active
ANZ_next
ANZ_reset
ANZ_MDS_present
ANZ_Read_0
ANZ_ECC
LR_bat
battery_low
error
ready
DBB 18
DBB 19
ANZ_DIR_change
15
14
13
12
11
10
9
8
7
6
5
ÉÉ
ÉÉ
4
ÉÉÉ
ÉÉÉ
3
2
ÉÉÉ
ÉÉÉ
1
0
init_run
←
Relative address in UDT 10
Must be set by the user
Essential that user
scan
Optional scanning bits
ÉÉ
Figure 3-1
Command and status word BEST with names of variables