Block Specifications
2-5
FC 56
J31069-D0155-U001-A0-7618
2.4
Number of MOBY Channels Which Can Be Connected
Each MOBY channel occupies 1 word in the input and output area of a SIMATIC
S7. The maximum number of MOBY modules permitted by the SIMATIC can
always be used. The following table gives you an overview.
Table 2-3
Number of MOBY channels
S7 CPU Type
315-2 DP
316-2 DP; 318-2 DP
416; 417; CP 443-5 Ext.
Max. no. of
ASMs
Max. no. of
SLGs
(channels)
Max. no. of
ASMs
Max. no. of
SLGs
(channels)
Max. no. of
ASMs
Max. no. of
SLGs
(channels)
ASM 475 (central)
1
32
64
32
64
–
–
ASM 475 (distributed
via ET 200M)
2
64 x 7
896
123 x 7
1722
123 x 7
1722
ASM 473 (distributed
via ET 200X)
3
64 x 7
448
123 x 7
861
123 x 7
861
ASM 452
64
64
123
123
123
123
1 The central layout can contain up to 3 expansion racks. A DP connection is not necessary with this layout.
2 With distributed layout, up to 7 MOBY modules (ASM 475) can be installed in each ET 200M.
3 Up to 7 ASM 473s can be installed in one distributed I/O ET 200X.
Summary of Contents for MOBY FC 56
Page 12: ...Introduction 1 6 FC 56 J31069 D0155 U001 A0 7618 ...
Page 63: ...5 1 FC 56 J31069 D0155 U001 A0 7618 Sample Applications 5 ...
Page 80: ...Sample Applications 5 18 FC 56 J31069 D0155 U001 A0 7618 ...
Page 90: ...Entry Exit Check of an MDS in an SLG Field 6 10 FC 56 J31069 D0155 U001 A0 7618 ...
Page 94: ...System Configuration 7 4 FC 56 J31069 D0155 U001 A0 7618 ...
Page 100: ...Commissioning Guidelines 8 6 FC 56 J31069 D0155 U001 A0 7618 ...
Page 101: ...9 1 FC 56 J31069 D0155 U001 A0 7618 Error Messages and Trouble Shooting 9 ...
Page 152: ...Programming MOBY ASM on PROFIBUS DP V1 B 30 FC 56 J31069 D0155 U001 A0 7618 ...