MOBY Commands
4-5
FC 56
J31069-D0155-U001-A0-7618
DIR: Read directory (see chapter 4.2.10)
The parameters of all existing files are read to DAT_DB_number/
DAT_DB_address.
MDS-STATUS: Read information about the operating status of the MDS
Reads MDS specific data to DAT_DB_number/DAT_DB_address.
This option can be used to set whether information is to be read via the physical
MDS or the logical MDS (filehandler).
END: Conclude communication with the MDS (see chapter 4.2.11)
The command is recommended when a scanning_time other than 0 (standby time)
is parameterized. Execution of this command optimizes the lifespan of the MDS
battery. Execution of an additional MDS command will now be delayed until the
sleep_time of the MDS expires.
Sleep_time can be poled with the MDS-STATUS command.
TRACE: Absolute MDS read (see chapter 4.2.13)
The contents of MDS memory are read to DAT_DB_number/DAT_DB_address
from a physical start address and with a given length.
(Test function)
MOVE: Save system data from the filehandler (dir FAT + checksum)
Dir FAT + checksum of the corresponding SLG station is saved in a data
block.
S
After a power failure, this information can be transmitted directly to the
ASM (filehandler) using a LOAD command. The checksum of the incoming
MDS will correspond again with the internal checksum in the filehandler. The
process can continue immediately at full transport speed.
S
Invoking the MOVE command is recommended after a corresponding
modification to a directory (checksum change: indication with variable
ANZ_DIR_change). Saving system data with MOVE is only recommended if
MOVE/LOAD is in general use.
LOAD: Transmit system data to ASM (see chapter 4.2.19)
This command can be invoked by the user to transmit data saved with MOVE to
the filehandler. Following a power failure, a LOAD command should be issued
immediately after the RESET command (only if LOAD/MOVE is in general use).
Summary of Contents for MOBY FC 56
Page 12: ...Introduction 1 6 FC 56 J31069 D0155 U001 A0 7618 ...
Page 63: ...5 1 FC 56 J31069 D0155 U001 A0 7618 Sample Applications 5 ...
Page 80: ...Sample Applications 5 18 FC 56 J31069 D0155 U001 A0 7618 ...
Page 90: ...Entry Exit Check of an MDS in an SLG Field 6 10 FC 56 J31069 D0155 U001 A0 7618 ...
Page 94: ...System Configuration 7 4 FC 56 J31069 D0155 U001 A0 7618 ...
Page 100: ...Commissioning Guidelines 8 6 FC 56 J31069 D0155 U001 A0 7618 ...
Page 101: ...9 1 FC 56 J31069 D0155 U001 A0 7618 Error Messages and Trouble Shooting 9 ...
Page 152: ...Programming MOBY ASM on PROFIBUS DP V1 B 30 FC 56 J31069 D0155 U001 A0 7618 ...