Short Description of the ASM Hardware
A-6
FC 56
J31069-D0155-U001-A0-7618
Input parameters for ASM 473
Assignment takes place in UDT 10 (see chapter 3).
Table A-2 Input parameters for ASM 473
Address
Name
Permissible Values
Commentary
+0.0
ASM_address
0, 4, 8, 12, ...
Automatic or manual address
assignment
Each ASM 473 occupies 4 bytes of I/O
in the peripheral area of the controller.
+2.0
ASM_channel
1
1 channel per ASM
+8.0
MDS_IO_control
B#16#0, 1, 4, 5
Enable/disable presence check
+9.0
ECC_mode
TRUE, FALSE
TRUE is only permitted when
MOBY_mode is parameterized with 1.
+9.2
priority_RW
TRUE, FALSE
+9.3
priority_RWD
TRUE, FALSE
+10.0
MOBY_mode
B#16#1, 5, 6
MOBY I/U
+11.0
scanning_time
B#16#00 ... FF
A value other than 00 is only recom-
mended when MOBY_mode was
parameterized appropriately (see
+12.0
SLG_number
B#16#0001 ... FFFF
The test function is on for FFFF (see
+14.0
distance_limiting
B#16#05, 0A, 0F, 14,
19, 1E, 23
+15.0
multitag
B#16#1
+16.0
field_ON_control
B#16#0, 1, 2
+17.0
field_ON_time
B#16#00 ... FF
Command table of the ASM 473
The ASM 473 processes all the commands described in chapter 4.
Summary of Contents for MOBY FC 56
Page 12: ...Introduction 1 6 FC 56 J31069 D0155 U001 A0 7618 ...
Page 63: ...5 1 FC 56 J31069 D0155 U001 A0 7618 Sample Applications 5 ...
Page 80: ...Sample Applications 5 18 FC 56 J31069 D0155 U001 A0 7618 ...
Page 90: ...Entry Exit Check of an MDS in an SLG Field 6 10 FC 56 J31069 D0155 U001 A0 7618 ...
Page 94: ...System Configuration 7 4 FC 56 J31069 D0155 U001 A0 7618 ...
Page 100: ...Commissioning Guidelines 8 6 FC 56 J31069 D0155 U001 A0 7618 ...
Page 101: ...9 1 FC 56 J31069 D0155 U001 A0 7618 Error Messages and Trouble Shooting 9 ...
Page 152: ...Programming MOBY ASM on PROFIBUS DP V1 B 30 FC 56 J31069 D0155 U001 A0 7618 ...