background image

JAO15 / JAO18

User Guide

Smart Terminal for the patient bedside

K5903250/01
10/03/2016

Summary of Contents for JAO18

Page 1: ...JAO15 JAO18 User Guide Smart Terminal for the patient bedside K5903250 01 10 03 2016...

Page 2: ...Barco NV President Kennedypark 35 8500 Kortrijk Belgium Phone 32 56 23 32 11 Fax 32 56 26 22 62 Support www barco com en support Visit us at the web www barco com Printed in Belgium...

Page 3: ...10 3 Operation 13 3 1 On Off switching 13 3 2 Service call 13 3 3 USB charging 14 3 4 HDMI input 14 4 Cleaning 15 4 1 Cleaning instructions 15 5 Important information 17 5 1 Safety information 17 5 2...

Page 4: ...Table of contents 2 K5903250 JAO15 JAO18 10 03 2016...

Page 5: ...web IPTV VoIP for patient entertainment 16 9 15 6 JAO15 or 18 5 JAO18 1366x768 Fanless LED Panel Computer Intel Celeron J1900 Quad Core Low Consumption CPU Flat Panel by Resistive JAO15 or PCAP JAO18...

Page 6: ...rpose configurable power key Please refer to the SDK documentation for more information about the different power key configura tion options 4 Combined SCR and RFID reader Combo Smart Carder Reader SC...

Page 7: ...connector 7 Barcode scanner optional on JAO18 not supported on JAO15 8 Rear IO area SC 19V Image 1 4 Functional earth blind fastener 19V DC power supply input connector 6P6C RJ11 service call SC conne...

Page 8: ...1 Introduction 6 K5903250 JAO15 JAO18 10 03 2016...

Page 9: ...ch the wire to the functional earth blind fastener Image 2 1 WARNING When you unplug the power cable always pull the plug never pull the cable Although the JAO15 and JAO18 have a very low standby powe...

Page 10: ...nt CAUTION Prior to removing any service door make sure the unit s power is off and disconnected from the power sources to prevent electric shock or system damage To fully disengage the power to the u...

Page 11: ...ck the volume before listening the JAOHandset and do not listen at high volume levels for long periods To switch the position of the JAOHandset L R The default mounting position of your JAOHandset is...

Page 12: ...ite dot to white dot pin Image 2 8 3 Use the screws from the handset box to firmly attach the handset to your terminal Image 2 9 2 5 VESA mounting To mount the JAO15 JAO18 on a VESA solution Your JAO1...

Page 13: ...e washers W a different screw length L should be selected Please respect the following rule to select an appropriate screw length Lmin T W 4 mm Lmax T W 5 5 mm T W Lmin Lmax Image 2 11 CAUTION Use onl...

Page 14: ...2 Installation 12 K5903250 JAO15 JAO18 10 03 2016...

Page 15: ...t and the status LED of the JAOHandset can be detected controlled on the RJ11 Service Call connector of your JAO15 JAO18 Please refer to the connector pinout below for more details The electrical sign...

Page 16: ...m USB ports USB charging is not possible via the USB ports at the back of your terminal 3 4 HDMI input Overview The JAO15 and JAO18 are capable of playing High Definition video and audio of any HDMI c...

Page 17: ...Detergents with fluoride Detergents with ammonia Detergents with abrasives Steel wool Sponge with abrasives Steel blades Cloth with steel thread CAUTION Take care not to damage or scratch the front gl...

Page 18: ...4 Cleaning 16 K5903250 JAO15 JAO18 10 03 2016...

Page 19: ...been dropped and damaged The equipment has obvious signs of breakage Installation mounting When installing the equipment in a cupboard or another closed location heed the necessary space between the s...

Page 20: ...your particular country Grounding Optionally earth the equipment by connecting the functional earth blind fastener to a grounded outlet by means of a wire with at minimum AWG18 size according to natio...

Page 21: ...formance of procedures other than those specified herein may result in hazardous radiation exposure Recycling For more information about recycling of this equipment please contact your local city offi...

Page 22: ...y participating in separate collection of batteries you will help to ensure proper disposal and to prevent potential negative effects on the environment and human health Turkey RoHS compliance T rkiye...

Page 23: ...to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device This Cla...

Page 24: ...000 3 3 Complies The JAO15 JAO18 is suitable for use in all establishments including domestic establishments and those directly connected to the public low voltage power supply network that supplies b...

Page 25: ...5 cycle 40 UT 60 dip in UT for 5 cycles 70 UT 30 dip in UT for 25 cycles 5 UT 95 dip in UT for 5s Mains power quality should by that of a typical commercial or hospital environment If the user of the...

Page 26: ...omer of the user of the JAO15 JAO18 can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equip ment transmitters and the JAO15...

Page 27: ...icates the device meets the requirements of the applicable EC directives Indicates compliance with Part 15 of the FCC rules Class A or Class B Indicates the device is approved according to the UL Reco...

Page 28: ...r Indicates the manufacturing date Indicates the temperature limitations6 for the device to safely operate within specs Indicates the device serial number Indicates the device part number or catalogue...

Page 29: ...or damaged if not handled carefully when being stored Indicates a device that needs to be protected from moisture when being stored Indicates the storage direction of the box The box must be transpor...

Page 30: ...demarks and registered trademarks are property of their respective owners Copyright notice This document is copyrighted All rights are reserved Neither this document nor any part of it may be reproduc...

Page 31: ...1 IEC60950 1 CB ANSI AAMI ES60601 1 CAN CSA C22 2 No 60601 1 Weight 4 2 kg Audio Integrated stereo speakers 2 x 2 Watt down firing Internal digital microphone Backlight LED High luminance 300 cd m2 t...

Page 32: ...mory 1 slot DDR3L 1333 SO DIMM socket Support up to 8GB capacity Standard 2 GB installed Storage pressure 50 kPa to 106 kPA Operating temperature 0 C to 40 C Storage temperature 20 C to 60 C Operating...

Page 33: ...50 1 CB ANSI AAMI ES60601 1 CAN CSA C22 2 No 60601 1 Weight 4 8 kg Audio Integrated stereo speakers 2 x 2 Watt down firing Internal digital microphone Backlight LED High luminance 300 cd m2 typical Ba...

Page 34: ...front Audio User interface Capacitive 10 point Multi touch screen P CAP touch technology Note Resistive single touch optional available from OEM program Multi purpose capacitive touch keys in glass fr...

Page 35: ...4 7 0 1 mm 64 1 0 1 mm 269 7 0 1 mm 267 0 0 1 mm 50 0 0 1 mm 32 1 0 1 mm Image 5 1 Dimension drawing JAO18 482 0 0 1 mm 66 0 0 1 mm 62 5 0 1 mm 165 7 0 1 mm 99 6 0 1 mm 87 8 0 1 mm 308 2 0 1 mm 302 0...