Siemens Mobility Limited
Sopers Lane, Poole, Dorset
BH17 7ER
Version
11
Page 78 of 117
Status
Issued
Last Editor
Jeerh, Manpreet
Date
March 2020
Document
Name
WIMAG GENERAL HANDBOOK
Doc. No.
667/HB/47200/000
Copyright
©
Siemens Mobility Limited 2012. All Rights Reserved.
Figure 59 : Mains Connection for 24V DC PSU (left: /200 variant;
right: /300 variant)
If the auxiliary MCB is not available or all neutral block terminations are occupied, an
additional MCB can be fitted to the Master Switch Panel. This will be mounted on the DIN
rail behind the blanking panels and cabled from the mains in on the adjacent AUX MCB.
Instructions can be found in the documentation referenced below;
Table 14 : Pole Mounting Kit Document Reference
WARNING:
The controller Master Switch MUST be in the OFF position before
mains cabling is attempted. It must remain in the OFF position until all mains
cabling is completed. DO NOT cable the WiMag rack assembly unit while the
controller cabinet is live.
Part Number
Document Description
667/GA/27121/000
OTU Supply Kit Assembly