Siemens Mobility Limited
Sopers Lane, Poole, Dorset
BH17 7ER
Version
11
Page 112 of 117
Status
Issued
Last Editor
Jeerh, Manpreet
Date
March 2020
Document
Name
WIMAG GENERAL HANDBOOK
Doc. No.
667/HB/47200/000
Copyright
©
Siemens Mobility Limited 2012. All Rights Reserved.
B.2.3 Count Detection mixed traffic
Install and configure as per the VA installation guidelines above.
Note
: Multiple bikes that cross the virtual detection zone simultaneously will be counted as a
single bike.
B.3 Mixed Traffic : Bicycles and Pedestrian
In general the separation between bicycles and pedestrians is poor and so these types
of arrangements are not recommended without the customer being made fully aware.
B.3.1
Stop line for mixed bikes and pedestrians
Refer to section B.1.1 for general installation and setting instructions.
•
Sample Rate
– 4Hz
•
Detection Distance
- 6 Ft
•
Auto baseline Sensitivity
– 4
•
Use Motion
– Not Set
•
Latch Car Subchannel
– Not Set
Figure 76 : Installation and Configuration for Mixed Bike and Pedestrian
Traffic - Stopline