Siemens Mobility Limited
Sopers Lane, Poole, Dorset
BH17 7ER
Version
11
Page 62 of 117
Status
Issued
Last Editor
Jeerh, Manpreet
Date
March 2020
Document
Name
WIMAG GENERAL HANDBOOK
Doc. No.
667/HB/47200/000
Copyright
©
Siemens Mobility Limited 2012. All Rights Reserved.
Double
Socket Arm
AP / Repeater
Bracket
Mounting
Balls
Figure 45 : Ball and Socket Mounting Detail
10.1.1 Mounting the Access Point
Table 10 : Signal Head Mounting Kit Document Reference
Due to cabling requirements, it is recommended that access points are mounted on traffic
signal poles. A specially designed L-bracket allows the access point to be fixed to the top
of a traffic signal head.
The following steps provide for the mounting of the access point above a signal head;
1. Remove the rear bolt from the signal head mounting bracket.
2. Replace with the M10 bolt provided.
3. Fit the access point L bracket using the M10 washer and nut provided, making use
of the front signal head mounting for anti-rotation.
4. Attach the double socket arm to the L-bracket.
5. Attach the AP to the double socket arm.
6. Orientate the AP in the direction depicted, within the junction/installation drawing,
and tighten the double socket arm to secure.
Part Number
Document Description
667/CI/47230/000
Installation instructions for Signal Head Mounting Kit