4.5.2
Front Panel Description
Figure 20 : Standard Interface : Front Panel
4.5.3
Status LEDs Indications
The WIMAG Standard Interface Card detector provides a visual indication of output
in the form of LEDs, these will be visible in all ambient light conditions:
•
1x Fault State
– Red : will only be ‘ON’ when any one of the mapped detectors is
in fault state or the Access Point reports lost communication to that detector.
•
1x System Run
– Red : This in normally ‘ON’ when the card status is considered
good.
•
1 x SW Run
– Red : This in normally ‘ON’ when the card software is running.