Siemens Mobility Limited
Sopers Lane, Poole, Dorset
BH17 7ER
Version
11
Page 53 of 117
Status
Issued
Last Editor
Jeerh, Manpreet
Date
March 2020
Document
Name
WIMAG GENERAL HANDBOOK
Doc. No.
667/HB/47200/000
Copyright
©
Siemens Mobility Limited 2012. All Rights Reserved.
Figure 39 : Recalibrate Timeout Setting
5. International Mode: The access point should be set to international mode. This setting
ensure that the ‘recalibration timeouts’ drop down list will only have the appropriate
values required for HA approval. This setting is managed by selecting the Access Point
within TrafficDot, which displays the
Access Point Config Window
. Within this
window, click
AP Config
and open the
Detection
tab. At the bottom of the tab select
‘
International Mode
’.
6. Set Access Point Colour Code: Selecting the Access Point within TrafficDot opens the
Access Point Config Window
. Within this window, click
AP Config
and open the
Advanced
tab. The junction colour code should then be copied from the configuration
spreadsheet into the
AP Colour Code
field.
7. Siemens protocol must be switched on within the access point to ensure correct
communications with the standard interface card. Open the
System Config - Other
tab in the
Access point Config Window
and click
Custom Application Settings
,
then check the
STS Enable
box to switch Siemens protocol on.