Installation of the Repeater and FlexNode
This section deals with the mounting of the repeater units. The repeater uses a similar
ball and socket fixing mechanism as per the access point.
One of two mounting kits have been made available. The first is designed for signal head
mounting (667/1/47230/000) (same as that used for mounting Access Points). The second
is a pole mounting banding kit (667/1/47235/000), which will be used for attachment to
existing poles such a lighting columns. The later is typically used with repeaters.
11.1 Pole Mounting Banding Kit
Repeaters, where possible, are to be affixed to street lighting columns as this gives an
extended range of options for mounting height without the need for specialist mounting
equipment. A simple clamping band is used to attach a square plate bracket to the pole
and the double socket arm then mounts the repeater to the bracket.
Figure 48 : Square Plate and Clamping Band