Siemens Mobility Limited
Sopers Lane, Poole, Dorset
BH17 7ER
Version
11
Page 67 of 117
Status
Issued
Last Editor
Jeerh, Manpreet
Date
March 2020
Document
Name
WIMAG GENERAL HANDBOOK
Doc. No.
667/HB/47200/000
Copyright
©
Siemens Mobility Limited 2012. All Rights Reserved.
11.3 FlexNode Repeater (aka Line Power repeater) Power Connection
Power to the Line Powered Repeater (LPR) will be transmitted via spare cores of existing
pole cables running to that pole. The kit 667/1/47258/000 contains the parts required to
enable this. Additional equipment required for mounting the LPR is listed in the table
below.
Siemens Part Number
Document Description
667/1/47249/000
WIMAG EXTENSION MTG KIT - ACCESS POINT
667/1/47225/X00
X = 0, Grey
X = 1, Black
WIMAG EXT BRKT CLAMP ASSY - DIA 114
Table 11-2 : Line Powered Repeater signal pole mounting kits
1. Assign and terminate two spare cores of signal cable to the terminal block
attached to the controller cabinet rear panel (as instructed in section 13.3).
Figure 49 : Terminal block on controller cabinet rear additional panel
2. Connect the shorter of the supplied 2-core link cables to the terminals in the top
cap terminal block with the corresponding core colours. Feed the cable through to
the red aspect box.
3. Drill a 20 mm hole using the rear dimple on the side of the aspect box and fit the
supplied M20 cable gland.