Siemens Mobility Limited
Sopers Lane, Poole, Dorset
BH17 7ER
Version
11
Page 54 of 117
Status
Issued
Last Editor
Jeerh, Manpreet
Date
March 2020
Document
Name
WIMAG GENERAL HANDBOOK
Doc. No.
667/HB/47200/000
Copyright
©
Siemens Mobility Limited 2012. All Rights Reserved.
Figure 40 : Enable STS setting
8. Set Access Point IP Address: The Access Point IP address can be set within the
System Cnfig - Network
tab of the
Access point Config Window
. The new IP
address is to be copied from the junction configuration spreadsheet into the
IP
Address
field. All other fields in this tab can be left blank.
9.
Ensure the 'Apply’ button is pressed at the bottom so that all the settings are applied.
10. It is recommended that the access point is rebooted at this stage.
7.3.5
Configuration for SCOOT Systems
The standard SCOOT loop detection area is normally expected to be 2m x 2m. The
detection zone of the WiMag sensor is likely to be in the region of 1.5m x 1.5m. Therefore,
in order to ensure correct emulation of a SCOOT loop, an additional detection extension
is applied to the detect output. This has the effect of elongating the detection area.
The following steps should be repeated for each sensor.
1. Selecting a sensor within TrafficDot opens the Sensor
Config
Window.
2.
Select the ‘
Card Addresses
’ tab.
3.
Add a values of 100 in the field titled ‘
Extension (millisecs):
’.