Siemens Mobility Limited
Sopers Lane, Poole, Dorset
BH17 7ER
Version
11
Page 52 of 117
Status
Issued
Last Editor
Jeerh, Manpreet
Date
March 2020
Document
Name
WIMAG GENERAL HANDBOOK
Doc. No.
667/HB/47200/000
Copyright
©
Siemens Mobility Limited 2012. All Rights Reserved.
7.3.4
Final Access Point Configuration
1. If required the Access Point radio frequency channel can be selected within the
AP
Config - Radio
tab of the
Access Point Config Window
.
2.
Setting the frame rate: The communications frame rate can be set by going to the ‘
AP
Config’
screen. Select the ‘
Event
’ sub-tab. Adjust the ‘
Transmit Interval’
to
0.0625s
(below example shows 0.125s).
1
3.
The ‘
Extra Latency’
should also be set to ‘
0.125 sec
’ while the user is on the ‘
Event
’
tab. This will add a latency to the detection system but ensures the system has
suff
icient time to utilise the ‘detection timestamp’s reported by the sensors.
Figure 38 : Setting the Transmit Interval
4. Setting the timeout period: The detection timeout (retune) is to be set at 4 minutes as
default. This is
set by going to the ‘
AP Config’
screen. Select the ‘
Detection
’ sub-tab.
Adjust the ‘
Count Recalibrate Timeout
’ to 4 minutes. This timing can be adjusted
depending on application requirement.
1
This value should be set to 0.125s if tandem repeaters are to be used. This is a restriction of the
system.