Siemens Mobility Limited
Sopers Lane, Poole, Dorset
BH17 7ER
Version
11
Page 59 of 117
Status
Issued
Last Editor
Jeerh, Manpreet
Date
March 2020
Document
Name
WIMAG GENERAL HANDBOOK
Doc. No.
667/HB/47200/000
Copyright
©
Siemens Mobility Limited 2012. All Rights Reserved.
8
General Installation Instructions
8.1 Special Tools Required for Non-Civils Based Installation
The following non-standard tools are likely to be required when involved in the installation
of a WiMag vehicle detection system.
1. Ethernet Jack Crimping Tool (8000 Series Crimping Tool, RJ45 WE/SS UT)
2. Ethernet cable checking tool (Greenlee NC-500 CAT5 Cable Tester)
8.2 Order of Installation
The following order of installation can be used as a suggestion, in order to ensure an
orderly implementation of the WiMag vehicle detection system.
1. Install the WiMag Sensors
2. Install the Ethernet cabling
3. Install Access points and repeaters
4. Terminate the Ethernet cables and confirm correct assembly
5. Install WiMag Communications Rack or WiMag Loop Detector Replacement Card
as required.